Main burner orifice(s) and new gas conversion label are provided in conversion kit attached to manifold pipe. CONVERSION INSTRUCTIONS FROM NATURAL GAS TO (LP) PROPANE GAS 1. Turn OFF gas supply and electrical power to fireplace. 2. Remove lower front panel. 3. Unscrew regulator stem from gas valve and reverse regulator stem to the propane gas position and screw stem back into gas valve. The propane gas arrow will be pointing at the gas valve in the propane gas position. See Figure 37. 4. Open fo
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. — Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli- er’s instructions. • If you cannot reach your gas su
The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. HEATER INSTALLATION FOR DIRECT VENT Locating Wall Opening The recommended location for this furnace is on an outside wall. Locate wall studs so that wall vent opening will be located between wall studs. The wall opening required for venting is a 3 1/2” (89mm) minimum diameter opening. Refer to Figures 3 and 6
WARNING: 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Under no circumstances should this appliance be operated without the glass front or with a broken glass front. Replacement of the glass (with gasket) as supplied by the manufacturer must be done by a qualified service person. 4. Do not abuse the glass by striking or hitting the glass. WARNING: Do not use abrasive cleaners on glass. Do not attempt to clean glass when
The sign shall read, the venting, including but not limited to decks and porches, the in print size no less than one-half (1/2) inch in size, “GAS following requirements shall be satisfied: VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. 1. INSTALLATIONOFCARBONMONOXIDEDETECTORS. At the time of installation of the side wall horizontal vented 4. INSPECTION. The state or local gas inspector of the side gas fueled equipment, the installing plumber or gas fitter shall wall horizontally vented g
The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. EXTERIORGRADEFLUECENTER11/4” (3.2cm) MIN. 12” (30.5cm) MIN. FLOORPROTECTION Figure 27 Minimum Exterior Grade Dimension - Unit Without Pedestal FLOORPROTECTIONNOHEARTHREQUIREDEXTERIORGRADEFLUECENTER11/4” (3.2cm) MIN. 12” (30.5cm) MIN. Figure 28 Minimum Exterior Grade Dimension - Unit With Pedestal Page 24 2261