Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  

Jackson AJ-44TE

Descargado: 57Tamaño del archivo: 6 mb    Fabricar: Jackson  
Categoría: Lavavajillas

44 [1118mm] 52 [1321mm] 60 [1524mm] 601 4 [1530mm] 8 [203mm] 8 [203mm] 14 [355mm] Scrap Trough Minimum 21 [533mm] B 12 [307mm] 651 2 [1667mm] 1 [25mm] 661 2 [1692mm] 133 4 [346mm] 7 [178mm] SECTION 1: SPECIFICATION INFORMATION AJ-44T ELECTRIC - LEFT TO RIGHT 4 AJ-44T Series Technical Manual 7610-003-07-21 Issued: 03-21-2006 Revised: 09-29-2007 Right to Left Drive Unit Left Side Drive Unit Front View Right Side 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with C

Jackson 230 1 15 06401-003-10-22

Descargado: 53Tamaño del archivo: 2 mb    Fabricar: Jackson  
Categoría: Lavavajillas

Using the torque wrench or a torque nutdriver (if available) 14. Apply silicone to seal the well and hold the thermostat probe in torge the nuts holding the wires, jumpers and bus bars to 16 in-lbs. place. Applying silicone to the heater well 15. Reattach the incoming power lines to the heater, ensuring that you wire the heater correctly for either single or three phase operation. Single phase wiring Tightening the nuts holding the power lines 17. Ensuring that all non-essential personnel are cl

Jackson 200B

Descargado: 51Tamaño del archivo: 1 mb    Fabricar: Jackson  
Categoría: Lavavajillas

BOX 1060 HWY. 25E BARBOURVILLE, KY. 40906 April 19, 2007 PHONE (606) 523-9795 FAX (606) 523-9196 P/N 7610-100-45-00 (Revision E) REVISION REVISION DATE MADE BY APPLICABLE ECN DETAILS C 10-30-2000 MAW 5709 Update to current design. D 01-12-2004 MAW 6946 Added 200S model. E 02-10-2006 MAW 7006, 7231 Changed thermostat bracket from 05700-011-73-72 to 05700-01181- 64. Change rinse thermostat from 05930-12-71-29 to 05930510- 03-79. Delete thermostat mounting bracket and decal from booster tank assemb

Jackson AJ-64CE

Descargado: 49Tamaño del archivo: 10 mb    Fabricar: Jackson  
Categoría: Lavavajillas

L - Prewash water inlet 3/4" NPT 110°F-140°F M - Cold water thermostat plumbing connection 3/4" NPT - Optional Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. Table to Table Overall 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. 86 [2182mm] 94 [2386mm] 102 [2589mm] B Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 25 [637mm] 8 [204mm] 21 [535mm] 2034 [527mm] 83 4 [222mm] 113 4 [298mm] 143 4 [375mm] 6 [

Jackson 10U

Descargado: 48Tamaño del archivo: 819 kb    Fabricar: Jackson  
Categoría: Lavavajillas

3717 CHERRY ROAD MEMPHIS, TN 38118 (901) 366-4587 800-262-9155 FAX: (901) 366-4588 CALIFORNIA: BARKERS FOOD MACHINERY SERVICES 5367 SECOND STREET IRWINDALE, CA 91706 (626) 960-9390 800-258-6999 FAX: (626) 337-4541 service@barkers.com GCS SERVICE INC. LOS ANGELES, CA 800-822-2303 P & D APPLIANCE 4220-C ROSEVILLE ROAD NORTH HIGHLANDS, CA 95660 (916) 974-2772 800-824-7219 FAX:(916) 974-2774 INDUSTRIAL ELECTRIC SVC 5662 ENGINEER DRIVE HUNTINGON BEACH, CA 92649 (714) 379-7100 800-4573783 FAX: (714) 3

Jackson 24 LT

Descargado: 48Tamaño del archivo: 452 kb    Fabricar: Jackson  
Categoría: Lavavajillas

III. IV. V. VI. Description General Section Specifications Installation Instructions Detergent Control Chemical Dispensing Equipment Operating Instructions Preventative Maintenance Conserver 24LT Cam Timer Operation Instructions Conserver 24LTP Cam Timer Operation Instructions Troubleshooting Section Dimensions Parts Section Control Panel Assembly Electrical Panel Assembly Ordering Replacement Wire Conduit & Fittings Kickplate Assembly Chemical Feeder Pump Mounting Assembly Chemical Feeder Pump

Jackson AJ-44TS

Descargado: 48Tamaño del archivo: 6 mb    Fabricar: Jackson  
Categoría: Lavavajillas

Since the Side Loader is shipped mounted on the conveyor dishwasher there is no additional installation required for this option. As it is operated mechanically by the dishwasher it does not require any plumbing or electrical connections. This Side Loader does not require or add any additional electrical or mechanical devices to the unit which could create operational or maintenance problems. As designed the drive mechanism is powered by the conveyor drive motor on the dishmachine. An extension

Jackson AJ-44TG

Descargado: 46Tamaño del archivo: 6 mb    Fabricar: Jackson  
Categoría: Lavavajillas

Hard water makes dishmachines work harder and decreases efficiency. Again, it is important to remind operators that trying to perform corrective maintenance on the dishmachine could lead to larger problems or even cause harm to the operator. If a problem is discovered; secure the dishmachine using proper shut down procedures as listed in this manual and contact Jackson. Some problems, however, may having nothing to do with the machine itself and no amount of preventative maintenance is going to

Jackson 415 3 15 06401-003-10-28

Descargado: 42Tamaño del archivo: 2 mb    Fabricar: Jackson  
Categoría: Lavavajillas

Turn the unit on and allow it to fill normally. 18. Verify that there are no leaks around the heater. If there are, attempt to tighten it down as the tub will change shape slightly as it heats up. 19. Use the amp meter to take readings off of the power lines to the heater, verifying the amperage draw to the machine data plate. 20. Wait until the heater contactor kicks out (meaning that the tub has reached the appropriate temperature) and place the unit in DELIME mode by flipping the switch on th

Jackson AJ-66TE

Descargado: 42Tamaño del archivo: 6 mb    Fabricar: Jackson  
Categoría: Lavavajillas

Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 1 [25mm] Drive Unit Front View 751 2 [1919mm] 621 2 [1590mm] 29 [737mm] 6 [152mm] 10 [254mm] C A B 4 [102mm] 7 [178mm] D E 8 [203mm] 42 [1067mm] 41 [1041mm] 24 [610mm] 101 4 [260mm] F 24 [610mm] G 231 2 [599mm] 601 4 [1530mm] 661 4 [1684mm] Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 25 [635mm] 4 1/2 [114mm] 81 4 [210mm] 21 [533mm] B A F Table to Table Overall Prewash Plan View Section with Cold Water