If the ohmmeter reads zero or open, the cell should be checked for dirt on the face or shorted leads. If the face of the photocell is dirty, clean with soft cloth and replace. Check for the resistance change in the photocell from no flame to flame. If the cell still reads zero or open check the wiring from one end to the other for opens and across the leads for shorts. If no problem is found replace the cell and check once again for the resistance change. 5. If the photocell and primary safety
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. Description Dayton portable oil-fired heaters are designed to provide temporary heat. They must be used with adequate ventilation, 120V, 60 Hz electrical power, and kerosene, or No. 1 fuel oil. THEORY OF OPERATION 1. There are four basic systems within the heater: the fuel system, air system, ignition system, and flame-out control system. 2. An air pump on o
CHICAGO 60648 FORM 5S2514 01582 T T 0484/109/1M READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THE DAYTON HIGH PRESSURE HEATER! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. General Safety Information WARNING: • IMPORTANT: READ AND UNDERSTAND INSTRUCTION MANUAL BEFORE STARTING OR SERVICING! • IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS BODILY INJURY DUE TO HAZARDS OF FIRE OR EXPLOSION, CARBON MONOXIDE POISONING, BURN, AND ELECTRICAL SHOCK. • USE ON
Herramientas requeridas: desarmador # 2 de Philips Specifications Model........................................2ZRP8.............2ZRP9 Motor......................................Honda............Honda Potencia Nominal (Vatios CA).................................5000...............6500 Potencia Nominal Intermitente (Vatios CA).......6000...............7500 Voltaje Nominal (CA)......120V/240........120V/240 Maximo Amperaje..............35.0/25.0........62.5/31.3 Continuo Amperaje............41.7/2
If you see globules of water in the bottom, drain and flush the tank and filter with clean fuel, b. Refill with fresh, clean fuel. FORM 5S1792 MODELS 2E510A, 2E511 A, 3E218A & 3E219 01582. Trouble Shooting Chart (Continued) SYMPTOMS POSSIBLE CAUSE(S) CORRECTIVE ACTION Heater burns, but puffs 2. Dirty air filters causing reduced 2. Remove and clean the air filters. of smoke can be seen; air flow through nozzle, resulting Be sure air intake is not blocked. heater will not burn in low
Si el punta de desconexion de la energia esta fuera del alconce de la vista, asegure el interruptor en posicion abierta y coloque una etiqueta de advertencia para evitar la aplicacion inadvertida de energia. 5. Libere toda la presion dentro del sistema antes de dar servicio a cualquier componente. 6. Drene todos los liquidos del sistema antes de darle mantenimiento. 7. El motor de la bomba esta equipado con un dispositivo automatico de reajuste de proteccion termica, y podria arrancar inesperada
15. Insert screws through heater shell and into motor mount. Tighten screws firmly. 16. Turn heater on its side to access opening in bottom of base. Connect green wires from motor, transformer, and power cord to heater shell using ground nut (See Figure 5, page 10). 17. Attach black and white wires to terminal board (See Wiring Diagram, page 14, for correct locations). 18. Replace base tray. FAN 1. Remove motor, motor mount, and fan (See Motor, pages 7 and 8, steps 1 through 8) . 2. Clean fan us
IMPORTANT: Every possible circumstance that might involve a hazard cannot be anticipated. The warnings in this manual and on tags or decals affixed to the unit are therefore not all-inclusive. If a procedure, work method, or operating technique not specifically recommended by Dayton is used, you must make sure it is safe for you and others. You should also ensure that equipment will not be damaged or made unsafe by the operating or maintenance method you choose. Carbon monoxide poisoning may lea