Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  

Hobart 208-240/60/3

Descargado: 228Tamaño del archivo: 833 kb    Fabricar: Hobart  
Categoría: Lavavajillas

208-240/60/1 . 208-240/60/3 . 480/60/3 . 200-240/50/3* . 380-415/50/3* *Not submitted for UL/CUL Listing MODEL . AM15T OPTIONS AT EXTRA COST . Gas heat . Sense-A-Temp™ 70°F rise electric booster heater . Single point electrical connection for booster equipped machines (3 phase only) ACCESSORIES . 3.4" pressure regulator valve . Peg rack . Combination rack . Sheet pan rack . Splash shield for corner installations . Flanged and seismic feet . End of cycle audible alarm (field activated) . Delime n

Hobart AM15T

Descargado: 67Tamaño del archivo: 833 kb    Fabricar: Hobart  
Categoría: Lavavajillas

Electrical components are wired with type ST cord. Line disconnect switch NOT furnished. CYCLE OPERATION: The microcomputer-timing program is started by closing the doors, which actuates the door cycle switch. The microcomputer energizes the wash pump motor contactor during the wash portion of the program. After the wash, a dwell permits the upper wash manifold to drain. At the end of the dwell, the final rinse solenoid valve is energized. After the final rinse valve closes, Sani-Dwell (Hot Wate

Hobart FT900

Descargado: 66Tamaño del archivo: 3 mb    Fabricar: Hobart  
Categoría: Lavavajillas

2007) TABLE OF CONTENTS OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . 3 Machine Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Tank Filling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Dishwashing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hobart C44AW ML-104083

Descargado: 60Tamaño del archivo: 2 mb    Fabricar: Hobart  
Categoría: Lavavajillas

O (Feb. 2006) IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS

Hobart FT900D

Descargado: 59Tamaño del archivo: 3 mb    Fabricar: Hobart  
Categoría: Lavavajillas

6) Repeat steps 4 and 5 for each digit. a. After pressing ENTER on the fourth digit, you will immediately return to the ENTER SECURITY CODE? screen. 7) You will know you entered the code correctly if the letter in the lower left corner reads M. Refer to Machine Operation and Programming Security Levels on page 15 for more details on other letters that may appear. a. If it does not match, repeat steps 3 through 7. b. If it does match, continue to step 8. 8) Press the UP or DOWN keys repeatedly un

Hobart C88A ML-110042

Descargado: 55Tamaño del archivo: 2 mb    Fabricar: Hobart  
Categoría: Lavavajillas

It has a stainless steel tank and chamber with a welded stainless steel angle frame, stainless steel legs and stainless steel adjustable feet. Front inspection door(s) provide access to the interior of the wash/rinse chambers. CRS and CPW models also have a prewash inspection door. The C44A/AW, CRS66A/AW, CCS66A/AW, CPW80A/AW, C54A, CRS76A, CCS76A, CPW90A, C64A, CRS86A, CCS86A and CPW100A machines are capable of either high- or low-temperature operation. The C88A family is not available for low-

Hobart DISHMACHINE SR24C

Descargado: 53Tamaño del archivo: 333 kb    Fabricar: Hobart  
Categoría: Lavavajillas

120/60/1 (SR24C model only) . 120/208(3W)/60/1 (SR24H model only) . 120/240(3W)/60/1 (SR24H model only) OPTIONS . Detergent pump - factory installed (chemical sensing module included) MODELS . SR24H – High Temperature Sanitizing . SR24C – Chemical Sanitizing ACCESSORIES - field installed . Detergent and/or rinse agent pump (chemical sensing device suggested) . Chemical sensing device (SR24H only) . Stainless steel top and side panels . Stainless steel base with 6" legs . 17" stainless steel stan

Hobart DISHMACHINE SR24H

Descargado: 52Tamaño del archivo: 333 kb    Fabricar: Hobart  
Categoría: Lavavajillas

PUMP: Centrifugal-type, integral with motor, vertically mounted. Pump capacity is 45 U.S. gallons per minute. MOTOR: Built to Hobart specifications, 1.2 H.P., single phase, furnished for 120/60/1, 120/208(3W)/60/1 or 120/240(3W)/60/1 electrical specification. Factory sealed lubrication. RACKING: Will accommodate most racks from 10" x 20" (half racks) to 20" x 20". Will also accept 16" x 18" cafeteria trays. WASH AND RINSE CYCLE: Completely automatic, controlled by an electrically energized synch

Hobart FT-800

Descargado: 43Tamaño del archivo: 5 mb    Fabricar: Hobart  
Categoría: Lavavajillas

FT-800 SERIES DISHWASHER FOOD EQUIPMENT • Water and energy saving design through reduced water and tank heat usage and automatic pump shut down control through conveyor. • Common water, drain, electric and steam connections. • Exclusive load end flush system. • Built-in integral wiring channel. • Automatic temperature control and positive low-water heater and pump seal protection. • Built-in inherent motor overload protection with manual reset. • Built-in vent ducts—dampers and drip control. • I

Hobart C88A ML-110041

Descargado: 42Tamaño del archivo: 2 mb    Fabricar: Hobart  
Categoría: Lavavajillas

CS/RS-22 Lower Prewash Arm — Optional on the CRS and CCS models. DDU38 Unloader — Moves racks in a 90-degree arc from the unload end of the dishwasher to a dish table; this allows the machine to be placed in a corner or to be used where area at the unload end is limited. Separate Water Connection — Individual Fill (140°F) and Final Rinse (180°F min.) water connections are available on high-temperature, non-booster machines only. Booster Heater — Interwired and interplumbed 30 KW or 15 KW booster





Categoría