3-DESIRED DESIRED is displayed when the temperature display shows the desired temperature setting. 4-OUTSIDE OUTSIDE will be displayed when the temperature display shows the outdoor temperature. The outdoor temperature will be displayed every 4 seconds. 4 5-. .. The . .. is displayed when the heating or cooling system is running. 6-COOL COOLis displayed when the system is in Cool mode. 7-AUTO AUTOis displayed when in automatic changeover mode. 8-HEAT HEATis displayed when the system is in Heat m
7-AUTO AUTOis displayed when in automatic changeover mode. 8-HEAT HEATis displayed when the system is in Heat mode. 9-FAN FANis displayed when the fan is set to run continuously. 10-OFF OFFis displayed when the system is in the Off mode. 11-REMOTE REMOTE is displayed when the last command received by the thermostat was sent by a remote system. 12- Period Indicators MORN, DAY, EVE, or NITE is displayed when scheduled temperature changes are made by the thermostat programs. 13-HOLD HOLDis displaye
If the thermostat or system does not perform as stated above, recheck all wiring -See Troubleshooting Tips. INSTALLER SETUP This section describes the items that the installer must setup as part of the thermostat installation. The Installer Setup mode is used to configure the general operating parameters of the thermostat. When in Installer Setup mode: 1. The small digits on the top of the display are the item number. 2. The large blinking digits in the center of the display are the value of the
This will allow you to have different heating and cooling settings on Saturday and Sunday, than you normally would have for weekdays (Monday Friday). When programming the time schedules, the weekday time schedule is programmed first. The Saturday time schedule is programmed second, and the Sunday time schedule is programmed last. 8 SETTING TIME SCHEDULES To view or change the programming time schedules of your thermostat, press and the Prog key four times. The weekday MORN time will flash. 1. Us
A temperature sensor can be physically connected to the “Remote Temp. Sensor” terminals on the thermostat or the RC-2000 can obtain the outdoor temperature from a remote system. If the RC-2000 can not obtain the outdoor temperature, the heat pump compressor will not operate and the thermostat will only call for the auxiliary heat until the problem is resolved. When this occurs, the display will flash red and the “Problem With Outdoor Temperature Sensor. Some Heat Stages May Be Disabled” error me
All Rights Reserved CONTENTS INTRODUCTION ..................................1 DESCRIPTION ....................................1 MAINTENANCE ...................................1 OPERATION .....................................2 DISPLAY ........................................4 FILTER REMINDER ................................6 ANTICIPATION ...................................6 SETTING THE CURRENT TIME AND DAY ...............7 PROGRAMMING ..................................8 SETTING TIME SCHEDULES ...
There are several items that can be configured at the time of installation. These items have a check box (..) for your installer to indicate which features are used in your system. As an EPA ENERGY STAR Partner, Home Automation, Inc. has determined that this thermostat meets the ENERGY STAR guidelines for energy efficiency. MAINTENANCE Your new thermostat is maintenance free. There is no battery to install or replace. If necessary, clean unit carefully with a mild soap solution on a soft cloth.
FCC This thermostat has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. This product generates and can radiate radio frequency energy. Due to its low power design, it is unlikely to interfere with radio and TV communications. If it is suspected of doing so, the user is encouraged to try to correct the problem by reorienting the receiver's antenna, moving the receiver away from the product, or consulting an experienced radio/TV t
• The Balance Setpoint Limits can be adjusted according to the manufacturer’s specifications under “Balance Setpoint” – See Installation Settings. 3) When the RC-1000 makes a call for auxiliary heat, the heat pump compressor is turned off and the auxiliary heat is used exclusively. Heat Pump (2 Stage Heat / 1 Stage Cool) 9 876543 1 24VAC Common 24VAC "HOT" Auxilirary Heat Compressor Ground Fault Fan Compressor Relay Aux Heat Relay Fan Relay Fault Relay Reversing ValveEnergized in Cool Energized
If the up arrow is pressed at 11:45 PM, or the down arrow is pressed at 12:00 AM, the time display will be blank, indicating that no scheduled temperature changes will be made for that period. Your thermostat will follow a set of time scheduled programs on weekdays (Monday-Friday), on Saturday, and on Sunday. This will allow you to have different heating and cooling settings on Saturday and Sunday, than you normally would have for weekdays (Monday Friday). When programming the time schedules, th