Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  

Gilson Peltier Racks 854

Descargado: 0Tamaño del archivo: 87 kb    Fabricar: Gilson  
Categoría: Otros accesorios para la casa

852/853/854 Peltier Racks Cooling and Heating Racks with Stand-Alone Control ■ Flexible, accurate and programmable racks for heating and cooling from 4-40°C ■ Three versatile rack options: 852 for shallow-well plates, 853 for 2-mL vials and 854 for deep-well plates ■ Can be configured with the single-probe 215 Liquid Handlers or the Quad-Z 215Liquid Handler ■ Up to five Code 85X Series racks can be placed on the locator plate of the liquid handler, enabling the heating and/or cooling of up

Gilson Peltier Racks 853

Descargado: 0Tamaño del archivo: 87 kb    Fabricar: Gilson  
Categoría: Otros accesorios para la casa

Contact Gilson for assistance Programming (P): The rack is in the programming state. Contact Gilson for assistance Power Requirements Frequency: 50-60 Hz Voltage: 90-240V Current rating: 8.0A for 90-120V or 4.0A for 220-240V (max.); 6.0A for 90-120V or 3.0A for 220-240V (typical) Internal fuses: Five 5A subminiature PC board fuses to be replaced by service personnel only Software Via Gilson control software Communication Interface RS-232 or GSIOC Dimensions (w x d x h) 26.5 x 43.5 x 15.6 cm

Gilson Peltier Racks 852

Descargado: 3Tamaño del archivo: 87 kb    Fabricar: Gilson  
Categoría: Otros accesorios para la casa

Contact Gilson for assistance Programming (P): The rack is in the programming state. Contact Gilson for assistance Power Requirements Frequency: 50-60 Hz Voltage: 90-240V Current rating: 8.0A for 90-120V or 4.0A for 220-240V (max.); 6.0A for 90-120V or 3.0A for 220-240V (typical) Internal fuses: Five 5A subminiature PC board fuses to be replaced by service personnel only Software Via Gilson control software Communication Interface RS-232 or GSIOC Dimensions (w x d x h) 26.5 x 43.5 x 15.6 cm

Gilson MORTAR-PLASTER 600MP

Descargado: 0Tamaño del archivo: 388 kb    Fabricar: Gilson  
Categoría: Mezcladoras

Line up the holes and insert the L-shaped pin through the holes. SAFTEY CHAINS For transporting the mixer, slide the tow pole out as far as possible and insert the locking pin. When operating the mixer, slide the tow pole in and lock it in place. Make sure drum is locked in position and engine housing is closed and secured. 1. Cross the chains under the tow pole to prevent the tow pole from dropping to the ground if the mixer comes loose. 2. Pass chain around a frame member or secure bumper iron

Gilson MORTAR-PLASTER 1200MP

Descargado: 1Tamaño del archivo: 448 kb    Fabricar: Gilson  
Categoría: Mezcladoras

Brick should be thoroughly wet before laying, except in freezing weather. Bricks laid with the long dimension parallel to the face of the work are called stretches, perpendicular to the face are called headers. Bats (chalk bricks) should not be used except where necessary to make corners or to form patterns on the face of the walls. Walls are bonded or tied together longitudinally by overlapping stretches in successive courses. Transverse bond is obtained by making every sixth course headers wit

Gilson Minipuls 3

Descargado: 23Tamaño del archivo: 143 kb    Fabricar: Gilson  
Categoría: Formadores

Beltline Hwy., P. O. Box 620027, Middleton, WI 53562-0027, USA Telephone: (1) 800-445-7661 or (1) 608-836-1551 • Fax: (1) 608-831-4451 Gilson S.A.S. 19, avenue des Entrepreneurs - BP 145, 95400 Villiers le Bel, France Telephone: (33) 1-34-29-50-00 • Fax: (33) 1-34-29-50-20 LT800443E. Printed in France, May 2003. Specifications subject to change without notice. Gilson, Inc., Gilson S.A.S., and Cyberlab, Inc. are ISO certified. ISO 9001 Certified Ordering Information Gilson’s Minipuls 3 is availab

Gilson 600CM

Descargado: 2Tamaño del archivo: 181 kb    Fabricar: Gilson  
Categoría: Mezcladoras

Read these messages carefully. The following precautions are suggested to help prevent accidents. Read and practice the following precautions before operating this equipment. Equipment should be operated only by those who are responsible and have been properly instructed. 1. Read all operating and maintenance instructions before operating or servicing mixer. Test run empty prior to actual use. 2. A mixer is only as safe as its operator. Give complete and undivided attention to the operation of t

Gilson 51/2CU.FT. 59015C

Descargado: 1Tamaño del archivo: 168 kb    Fabricar: Gilson  
Categoría: Mezcladoras

Hold the tilt handle and unlock the stop lever. Dump concrete to either side by tilting the tilt handle in the direction required. Before reloading the mixer, slowly pour a pail of water over the lip of the drum, permitting water to clean the inside of drum. When cleaned, dump water. Now you are ready for your next batch. CLEANING THE MIXER After each run of concrete has been poured, do the following: With the drum rotating, spray water into drum permitting the water to run down the inside and o

Gilson 215

Descargado: 3Tamaño del archivo: 1 mb    Fabricar: Gilson  
Categoría: dispositivos robóticos

1-1 Description ............................................................................ 1-2 Unpacking............................................................................. 1-3 Standard Equipment .................................................... 1-4 Accessories ..................................................................... 1-4 Customer Service ................................................................. 1-5 Technical Specifications ......................................