Iniciar sesión:
Clasificado: Nombre ↓   Descargas   Tarifa   Tamaño ↑  

Breckwell 1991 MODELS P24FS

Descargado: 6Tamaño del archivo: 315 kb    Fabricar: Breckwell  
Categoría: chimeneas

per hour to help you plan your refueling schedule. Please note these rates are only approximate. The "Max" setting feeds approximately 4Vi lbs./hour. The convection blower speed varies directly with feed rate. The "High Fan" switch overrides this variable speed function. It will set the convection blower speed to high at any feed rate setting. 3.5 Optional Thermostat A remote thermostat will help you maintain a constant house temperature automatically. A low voltage, normally closed thermostat

Breckwell 1991 MODELS P24I

Descargado: 10Tamaño del archivo: 315 kb    Fabricar: Breckwell  
Categoría: chimeneas

P.O. Box 2501 Eugene, Oregon 97402 MODEL P24I MODEL P24FS Fireplace Insert Freestanding Stove 6-90 SAFETY NOTICE: If your appliance is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. ALL UNITS TESTED AND LISTED BY I.C.B.O. TL128 accredited ©NATIONAL STEELCRAFTERS OF OREGON. INC. Thank you for purchasing the Breckweil Pelle

Breckwell ECONOMY P22FSA

Descargado: 7Tamaño del archivo: 743 kb    Fabricar: Breckwell  
Categoría: Los calentadores de gas

You should adjust the damper based on the fire’s appearance. A low, reddish, dirty fire can be improved by pulling the damper out slightly. A “blow torch” fire can be improved by pushing the damper in a bit. As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should be more open. Through trial and error, you will find the best setting. Consult your dealer if you need help. NOTE: On “1”, damper should be out approximately 1/8” to .”. I

Breckwell ECONOMY P22FSL

Descargado: 8Tamaño del archivo: 743 kb    Fabricar: Breckwell  
Categoría: Los calentadores de gas

Ashes must be disposed in a metal container with a tight lid and placed on a no combustible surface well away from the home structure. · This stove must be connected to a standard 120 V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath, in front of, or over the stove. · The exhaust system should be checked, at a minimum, at least twice a year for any build up of soot or creosote. · Keep foreign objects out of t

Breckwell ECONOMY P22I

Descargado: 6Tamaño del archivo: 743 kb    Fabricar: Breckwell  
Categoría: Los calentadores de gas

• Use 4” pipe if you have more than 15 feet of equivalent vent length. • Horizontal runs shall not exceed 10 feet of EVL. • It is recommended that vertical runs be a minimum of 8 feet. • To calculate EVL, use the following conversions: 90. elbow or “T” = 5 equivalent feet 45. elbow = 3 equivalent feet Horizontal Pipe Run = 1 equivalent foot per actual foot Vertical Pipe Run = 0.5 equivalent foot per actual foot NOTE: At altitudes above 3,000 feet, we suggest the use of 4” diameter vent at an EVL

Breckwell LUXURY SERIES P2000

Descargado: 5Tamaño del archivo: 568 kb    Fabricar: Breckwell  
Categoría: chimeneas

If the voltage is lower than full current, check the wiring. If the wiring checks out good, the board is bad. SMOKE SMELL COMING BACK INTO THE HOME Possible Causes: Possible Remedies: 1. There is a leak in the vent pipe system. Inspect all vent pipe connections. Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher. Also, seal joints with UL-181-AP foil tape. Also, make sure the square to round adapter piece on the combustion blower has been properly

Breckwell LUXURY SERIES P2000FS

Descargado: 3Tamaño del archivo: 568 kb    Fabricar: Breckwell  
Categoría: chimeneas

If only the 1 light is on, the stove is in the default (medium) setting. If the 1 & 4 lights are on, the stove is in the high trim setting for the low feed rate. If the stove is being burned on one of the two lower settings, advance to the next trim setting and try burning the stove. 28 8 TROUBLESHOOTING GUIDE HIGH LIMIT SWITCH KEEPS TRIPPING Possible Causes: Possible Remedies: 1. The convection blower is overheating and tripping the internal temperature shutoff. Clean any dust off of the windin

Breckwell LUXURY SERIES P2000I

Descargado: 3Tamaño del archivo: 568 kb    Fabricar: Breckwell  
Categoría: chimeneas

Airflow switch hose or stove attachment pipes for hose are blocked. Unhook air hose from the air switch and blow through it. If air flows freely, the hose and tube are fine. If air will not flow throw the hose, use a wire coat hanger to clear the blockage. 2. The air inlet, burnpot, interior combustion air chambers, combustion blower, or exhaust pipe are blocked with ash or foreign material. Follow all cleaning procedures in the maintenance section of the owner’s manual. 3. The firebox is not pr

Breckwell Luxury Series P2700

Descargado: 1Tamaño del archivo: 123 kb    Fabricar: Breckwell  
Categoría: Placa

For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions. PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by Breckwell Hearth Products Eugene, Orego

Breckwell P2000

Descargado: 7Tamaño del archivo: 685 kb    Fabricar: Breckwell  
Categoría: Placa

For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by National Steelcrafters of Oregon, Inc. D