In addition, the heater's low mass allows rapid start-up and fast response to controls. The patented RAYMAX heater features one-inch (25 mm) wide emitter strips that are individually replaceable for lower maintenance costs. Weighing only 5.5 lbs/ft2 (26.8 kg/m2), the heater is easy to mount. Applications • Thermoforming • Textile drying • Paint curing • Powder coating fusing • Shrink wrapping • Circuit board soldering Aluminized Steel Case Features and Benefits Replaceable emitters •
Other voltages are available. Terminals: Non-standard locations are also available. Please specify. Standard Dimensions: ±Xe inch (0.0625 mm) Typical Peak Energy Wavelength: 3-3.5 microns Specifications Heater Dimensions Min. Max. Increments Width: inches (mm) Length: inches (mm) Area: in (cm ) 1 (25.4) 6 (152.4) 6 (38.7) 36 (914.4) 70 (1778) 864 (5574.2) 1 (25.4) any any Note: Less than maximum length X width may exceed maximum area. How to Order To order your stock RAYMAX heater, spe
The control mode options include factory selected combinations of ON/ OFF, time proportioning, PI using manual reset and full PID. Input for the Series 160 is a relative humidity/ temperature sensor. Features include mechanical relay outputs, remote setpot, optional remote digital displays, and various cable lengths to accommodate remote sensor location. The Series 160 is also available as a RH/Temperature signal conditioner only, that can be interfaced to other Watlow controls. Specifications
IS SEC CYCLE TIME C = TIME PROPORTIONING 15°F BAND. 9 SEC CYCLE TIME D = TIME PROPORTIONING _25“F BAND. 5 SEC. CYCLE TIME OUTPUT LD MD KO A = 35A SPST 0 = 60A SPST G = 25A SPST B = 35A 2PST E = 60A 2PST H = 25A 2PST C = 35A 3PST F = 60A 3PST J = 25A 3PST UNE VOLTAGE 115 VAC 230VÄCT CONNECTIONS I - QUICK CONNECTS 2 = BARRIER STRIP SEÎPOT ASSEMBLY ~ i - INTFGftAL 2 = REMOTE ♦ SENSOR RANGE NO 600 = 50 TO 500"F 10 TO 260°C __TYPE J TC 601 = 50 TO IOOO”F 10 TO 538“C TYPE J T£_ 6
The control mode is time proportioning with automatic reset. There is a front panel adjustment for the proportional band and internal adjustments for the auto reset on all models and for cycle time on the solid state and relay output models. Access to internal adjustments is available by loosening just one screw and pulling the controller out of the case. Analog meter indication is available in the form of a deviation meter or a direct reading meter. In addition, there are front panel mounted L.
mA Input High: Represents the high current calibration point for Zone 2, input nAHI 20mA. Applies only to thermocouple and process input. Only applies to Zone 2 inputs. Thermocouple Compensator: Used to calibrate the thermocouple reference tC compensator for units with thermocouple input. Input 0.00mV compensated through Type J reference compensator (32°F/0°C). 4-20mA Output Low (Zone 1): Represents the process output low current calibration point for Zone 1. Applies to 0-5VDC and 4-20mA outputs
BOX 5580, Winona, MN 55987-5580, Phone: 507/454-5300, Fax: 507/452-4507 0600-0008-0000 Rev D $10.00 November 1995 Made in the U.S.A. Supersedes without change: W733-XSMN Rev D00 Contents Contents This manual is a supplement to the Series 733/734 Program Manual. It is for configuring, servicing and calibrating your control. Use this manual in conjunction with the Series 733/734 Program Manual and Data Communications manual. PageItem Chapter 1 3 Install and Wire the Series 733/734 3 Dimensions 3 P
. . . . . . . . . . . . . . . . . . . . . . . . . .go to page 1.1 • Experienced User . . . . . . . . . . . . . . . . . . . . .go to page 2.1 • Expert user . . . . . . . . . . . . . . . . . . . . . . . . . .go to page 2.1 Installers: • Installation . . . . . . . . . . . . . . . . . . . . . . . . . .go to page 2.1 • Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .go to page 2.3 Watlow Controls 1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota USA 55987-5580 Phone: (507) 454-5300
Consult your Watlow representative if vertical mounting is unavoidable. • Mount the heater near or below the lowest point on the engine block. Keep outlet nozzle pointed up, as indicated on the tank. Estimate kilowatt requirements with the following formula. First determine the engine displacement, then multiply: English Cubic inches X 3 = estimated wattage Metric Liters X 183 = estimated wattage Outlet Nozzle Sized for 1" I.D. W- 20 Mounting Bolts Vibration Isolator Bushings (2) Mountin
FREEFLEX® heats fluids up to 100°C (212°F) and maintains temperature during transfer from a reservoir to a point of use. In some applications, the tubing can actually serve as the reservoir for limited volumes of fluid, helping to reduce start-up times. For higher temperatures consult the factory. Watlow’s innovative design places the heating element and sensor directly in contact with the perimeter of the tubing to produce efficient, responsive heating and temperature control of the tube conten