READ AND KEEP FOR REFERENCE. INSTRUCTIONS Model PRO 3500hc Electrostatic Air Spray Gun 65 kV, HIGH CONDUCTIVITY, MANUAL GUN 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure For use with electrically conductive, solvent based coatings, including metal flake paint Part No. 222625, Series B NOTE: Any modification of genuine Graco parts or replacement of parts with non-Graco parts will void agency approvals. PRO 3500hc Electrostatic High Conductivity Air Spray Gun Part No. 223451 Conversion Kit To
If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
8. Install the capscrews and washers finger–tight. Torque the screws to 21.7 ft–lb (29 Nm) following the tightening pattern (Figure 4). Uneven tightening may cause the manifold to bind or jam. 1 4 23 5 8 7 6 3. Carefully examine each plunger for any scoring or Figure 4 cracking and replace as necessary. . . Servicing the V–Packings 5. Thoroughly clean the packing cavities and examine. NOTE: There are two types of packing kits: one is just packings, the other includes the packings, rings and reta
Sparks can ignite fumes from solvents and the fluid being pumped, dust particles, and other flammable substances, whether you are pumping indoors or outdoors, and can cause a fire or explosion and serious bodily injury and property damage. If you experience any static sparking or even a slight shock while using this equipment, stop pumping immediately. Do not use the system again until the problem has been identified and corrected. To reduce the risk of static sparking, ground the pump, surge su
NOTE: Stand on a stable surface and grip gun/spray wand firmly with both hands. Expect the gun to kick when triggered. 10. Release trigger to stop water flow. 11. Adjust spray for the task being performed by changing quick connect nozzle. See How To Use Spray Wand instructions in this section. SHUTTING DOWN 1. After each use, if you have applied chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. NOTE: Fa
. . . . . . . . . . . . . .6 Flush Before Using Equipment . . . . . . . . . . . . . .6 Integrated Air Control Module . . . . . . . . . . . . . . .6 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 PressureRelief Procedure . . . . . . . . . . . . . . . . .9 Cleaning Solutions . . . . . . . . . . . . . . . . . . . . . . .9 Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Starti
P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1993, Graco Inc. is registered to I.S. EN ISO 9001 45:1 RATIO PREMIER CARBON STEEL Cart-Mounted Airless Package WITH DURA-FLO 1800 DISPLACEMENT PUMP 315 bar, 31.5 MPa (4500 psi) Maximum Working Pressure 7 bar, 0.7 MPa (100 psi) Maximum Air Inlet Pressure Part No. 222973, Series B With High Pressure Fluid Filter Part No. 238144, Series B With High Pressure Fluid Filter, hose and gun 308215L Model 238144 Shown 05915 Important Safety Instructions R
1 YEAR -Limited warranty on all other air compressor components. 2 YEARS -Limited warranty on electric generator alternators. 1 YEAR - Limited warranty on other generator components. 2 YEARS -Limited warranty on pneumatic air tools as described in Porter-Cable general catalog. 1 YEAR -Limited warranty on pressure washers used in consumer applications (i.e. personal residential household usage only). 90 DAY -Pressure washers used for commercial applications (income producing) and service parts. 1
2. Turn prime/spray valve to SPRAY position. 3. Disengage inline valve safety latch, trigger the inline valve, and roll the surface until paint comes to roller. NOTE: Trigger the inline valve briefly only when you need more paint. Determine how often you must trigger the inline valve to maintain an even paint supply to the roller. 4. Increase pump pressure only if triggering inline valve cannot supply enough paint for your rolling speed. Relieve pressure, page 3, whenever you stop painting. 5. E
. . Installation A Husky pump B Husky surge suppressor H Fluid drain valve (required) S Dispense valve T Fluid drain line W Surge suppressor ground wire (required) See page 4 for installation instructions. Y Air motor ground wire (required) Z Container ground wire (required) Z S Fig. 2 Grounding a Surge Suppressor Hose must be conductive. Dispense valve nozzle must be in contact with the container. A H T Y B W Z air supply connection A H Y B W T air supply connection S Z Z Installation