Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  

Empire Products Wind Blaster Express FN33-S

Descargado: 5Tamaño del archivo: 196 kb    Fabricar: Empire Products  
Categoría: Los aficionados

You can hold it in the palm of your hand, pointing in whatever direction that you need a cooling breeze or you can flip it open and rest it on a table or desktop. The fan-head swivels so that you can position the cooling breeze in almost any direction. Battery Installation To install batteries into the Wind Blaster Express, you must open the battery compartment that is located on the base of the unit. Slide the compartment open and load in the batteries, matching the polarity (- and +) as sh

Empire Products VENTED ROOM HEATER RH-35-6

Descargado: 3Tamaño del archivo: 561 kb    Fabricar: Empire Products  
Categoría: Eléctrico

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer,

Empire Products VENTED ROOM HEATER RH-25-6

Descargado: 2Tamaño del archivo: 561 kb    Fabricar: Empire Products  
Categoría: Eléctrico

9. Open tees should not be used in the flue pipe. 10. Appliance must not be connected to a chimney flue that is servicing a separate solid-fuel burning appliance. For proper venting, do not attach a 90° elbow directly to draft diverter. If possible, attach 2 feet (.6m) of straight vent pipe before an elbow is used. Use 45° elbows if possible. Uninsulated single-wall metal pipe shall not be used outdoors in cold climates for venting gas utilization equipment. Ventilation and Combustion Air Room h

Empire Products SR-30T-3

Descargado: 0Tamaño del archivo: 996 kb    Fabricar: Empire Products  
Categoría: Eléctrico

circulating air passageways of the appliance be kept clean. • Due to high temperatures, the appliance should be located • DO NOT use this room heater if any part has been under out of traffic and away from furniture and draperies. water. Immediately call a qualified service technician to • Children and adults should be alerted to the hazard of inspect the room heater and to replace any part of the high surface temperature and should stay away to avoid control system and any gas control which has

Empire Products SR-18T-3

Descargado: 1Tamaño del archivo: 996 kb    Fabricar: Empire Products  
Categoría: Eléctrico

Figure 13 Oxygen Depletion Sensor Pilot (Figure 14) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows: 1. Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench. Figure 14 Warning: Never use needles, wires, or similar cylindrical objects toclean the pilot to avoid damaging the calibrated ruby thatcontrols the gas flow. THERMOSTAT OPERATION To ignite main burner, turn gas control kn

Empire Products SR-10T-3

Descargado: 3Tamaño del archivo: 996 kb    Fabricar: Empire Products  
Categoría: Eléctrico

Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 16009-1-0504 PARTS LIST PARTS LIST SR-18T SR-30T PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART NUMBER NUMBER DESCRIPTION NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBLY - LEFT 1 13348 CASING SIDE ASSEMBLY - LEFT 2 SR-090 CASING BACK 2 SR-041 CASING BACK 3 R-2313 PIEZO IGNITOR 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBLY - RIGHT 4 SR-008 CASI

Empire Products RH-50-6

Descargado: 2Tamaño del archivo: 1006 kb    Fabricar: Empire Products  
Categoría: Eléctrico

USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 12822-3-0406 Page 14 PARTS VIEW RH-50C & RH-65C Page 15 12822-3-0406 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS FRB-3 For Vented Room Heaters Models RH-50-(1, 2, 3, 4, 5, 6) RH-50C-1 RH-65-(1, 2, 3, 4, 5, 6) RH-65C-1 Figure 1 Figure 2 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion shoul

Empire Products RB)

Descargado: 2Tamaño del archivo: 1 mb    Fabricar: Empire Products  
Categoría: Eléctrico

To clean burner ports, disconnect the gas supply to the valve. Remove the burner assembly from the combustion chamber. Remove pilot burner from main burner and then remove the main burner. Force water into the ports and blow dry with vacuum cleaner air, or low pressure compressed air. The correct flame will be blue, extending past the thermopile. The flame will surround the thermopile just below its tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5" w.c. (1.245kPa)

Empire Products RB)

Descargado: 5Tamaño del archivo: 4 mb    Fabricar: Empire Products  
Categoría: Eléctrico

La flama correcta sera azul, extendiendose mas alla de la termopar. La flama se ubicara alrededor de la termopar un poquito mas abajo de su punta. Pilotos para gas natural necesitan ajuste cuando la presion de gas de entrada es mas de 5" w.c. (1.245kPa). Remueva el tornillo de la cubierta del piloto en la valvula y gire el tornillo de ajuste en el sentido de las manillas del reloj, para reducir la flama. Reinstale el tornillo de la cubierta del piloto para evitar fuga de gas en esta abertura de

Empire Products GWT-35-2(SG

Descargado: 0Tamaño del archivo: 4 mb    Fabricar: Empire Products  
Categoría: Eléctrico

Nunca use una llama expuesta para inspeccionar fugas. El aparato debe desconectarse de la tuberia a la salida de la valvula, y sellarse cuando se pruebe la presion de gas. .Nunca pruebe la presion de gas estando el calentador conectado; la valvula se danara! Una union para valvula de gas y para la conexion de tierra deben de instalarse en la linea de gas contracorriente de la valvula para ayudar durante su servicio. Se requiere segun el National Fuel Gas Code que una linea de gotera sea instalad





Categoría